This unit is a bench top single-output power supply.
The power supply has two meters; one to monitor the output voltage and one to monitor the output current.
The power supply will find wide application in schools, laboratories, and commercial engineering and testing departments, as well as with the advanced hobbyist.
Operating Instructions
(1) Connect the instrument to an AC power source using the line cord provided and turn the power switch ON.
For maximum stability, allow the instrument to warm up for at least 20 minutes.
(2) Set the voltage and current adjustment knobs to desired output.
Operating Cautions
Please note the following cautions when using your power supply, to prevent damage to the unit.
(1) Do not connect to equipment until all settings are complete.
(2) Verify that the AC voltage setting is the same as your available power BEFORE you apply power for the instrument.
(3) Do not connect a voltage that is greater than the output voltage to the terminals of the instrument.
SPECIFICATIONS
Output Voltage: 0 30 VDC
Output Current: 0 10 Amps
Current Limiting: 0 10 Amps continuously variable
Load Regulation: ±0.25% +3mV (1% to 100% of Rated Load)
Line Regulation: ±0.025% +2mV (10% Input Variation)
Riplle and Noise: 0.5mV RMS (to 10KHz)
Output Impedance: 0.2 Ohms (to 10KHz)
Power Requirements: 120VAC, 60Hz, 360W
Meter Ranges: Voltage& 0 30V
Current& 0 10A
Meter Accuracy: 2.5% of full scale
Protected against Short circuits
Fuse: Replace only with 8 Amp fast blow fuse, AGC8
Variable Output DC Power Supply
Constant Voltage / Constant Current
Coarse & Fine Adjustments
Voltage & Current Meters
Two Year Warranty
Weight: 12.5 KGS, (28lbs)
Dimensions: 215 (W) x 162 (H) x 312 (D) mm
8.5 (W) x 6.38 (H) x 12.5 (D) inches
FRONT PANEL
(1) POWER ON LED
(2) POWER ON - This is the main power switch.
(3) OUTPUT TERMINALS
(4) GROUND TERMINAL
(5) HI-LO SWITCH - When set to HI, the panel meter needle indicates the current on the top of the scale.
When set to LO, the needle indicates the current on the bottom of the scale. This allows for greater resolution in adjusting and reading low current settings.
(6) CC LAMP - Indicates that current is being limited.
(7) CURRENT ADJUST - This control adjusts the maximum current that the supply will output.
(8) CV LAMP - Indicates that voltage is being limited.
(9) COARSE/FINE VOLTAGE ADJUST - These two controls adjust the output voltage of the supply.
(10) VOLTAGE/CURRENT METERS - These two meters indicate the output voltage and current as measured at the output terminals.